How to upgrade...

Before you begin:

Download the upgrade file and save it on your hard disk.

The Camera server must be installed on an Ethernet the network using TCP/IP, see User’s manual or Quick Reference Guide. 

Disable any CRON Scripts or links to Web Pages that may reference the Camera Server during the flash procedure. 

Important Note: You must be in DOS and in the directory that contains the Upgrade File.
Example: C:\Axis\200p\1_42\

  1. Open a ftp connection to the unit you want to upgrade, from a command prompt. (I.e. you cannot use a ftp-program for this!) 
  2. Login as root. The default password for the root user is pass unless changed by the user. You must be logged in as the root user to flash the unit. 
  3. Change to binary transfer mode by typing bin and push the enter key. 
  4. Type hash and push the enter key. This will allow you to see the flash in progress. 
  5. Type the command put XXX.YYY flash and push the enter key. Change XXX.YYY to the name of the file you have downloaded and decompressed. Typically 200p_142.bin or axis200p.bin. 
  6. Wait for the flash load to finish, this may take 1-4 minutes. 

Your unit will automatically restart using the new firmware. 

C:\AXIS\200p\1_42>ftp 192.36.253.80.

Connected to 192.36.253.80.

220 AXIS 200pV1.41 Dec 11 1998 ready.
User (192.36.253.80:(none)): root
331 User name ok, need password
Password:
230 Root user logged in
ftp> bin
200 TYPE set to I.
ftp> hash
Hash mark printing On ftp: (2048 bytes/hash mark) .
ftp> put 200p_142.bin flash
200 PORT command successful.
150 Opening data connection for flash (192,36,253,80,5,75) (0 bytes), (mode binary).
###############################################################
###############################################################
########################################################
421-Transfer complete, flash programming finished OK.
Starting new software...
421 Reset, closing connection.
ftp: 2175752 bytes sent in 78.92Seconds 27.57Kbytes/sec.
ftp> bye