| Parameter | Description | Range |
| Device ID | This is the address of the connected device. Since the Sony EVI units operates in a daisy-chain configuration the first unit in the chain will have Device ID 1, the second unit will have Device ID 2 and so on. | 1-7 |
| Device type | Select which type of device that is used. | "EVI-G20/G21", "EVI-D30/D31", "EVI-D100/D100P", "EVI-D70/D70P" |
| Flip pan | If set to true, relative pan operations will be inverted | true, false |
| Flip tilt | If set to true, relative tilt operations will be inverted | true, false |
| Enable digital zoom | If set to false, digital zoom will never be used. Digital zooming will start at zoom value 7000. Only EVI-D100/D100P and EVI-D70/D70P support digital zoom. |
true, false |
| Parameter | Description | Range |
| Move Speed | Set the default speed to use for pan, tilt and zoom movements. | 1-100 |
| Block auxiliary commands | If true, the auxiliary command support for the device is disabled. Auxiliary commands may interfere with the drivers device control. |
true, false |
| Min field angle for digital zoom | 1/10 degrees (i.e. a value of 15 represents an angle of 1.5 degrees). See Mechanical Limits below. Only EVI-D100/D100P and EVI-D70/D70P support digital zoom. |
1-1000 |
| Movement Limits | Minimal value | Maximal value | Comment |
| Left | -30 | 30 | Limits for EVI-G20/G21 |
| Right | -30 | 30 | |
| Up | -15 | 15 | |
| Down | -15 | 15 | |
| Left | -100 | 100 | Limits for EVI-D30/D31 and EVI-D100/D100P |
| Right | -100 | 100 | |
| Up | -25 | 25 | |
| Down | -25 | 25 | |
| Left | -170 | 170 | Limits for EVI-D70/D70P (when mounted upside down, see notes below) |
| Right | -170 | 170 | |
| Up | -30 | 90 | |
| Down | -30 | 90 | |
| Zoom Limits | |||
| Zoom wide | 1 | 9999 | For EVI-D100/D100P and EVI-D70/D70P, digital zoom is 7000-9999 |
| Zoom tele | 1 | 9999 | |
| Focus Limits | |||
| Focus near | 1 | 9999 | |
| Focus far | 1 | 9999 | |
| Optical Data | |||
| Min field angle | 1 | 1000 | Degrees. Min field angel is at max optical zoom. |
| Max field angle | 1 | 1000 | |