FIRMWARE RELEASE NOTES ====================== Products affected: AXIS P5534-E PTZ Dome Network Camera Release date: 2017-06-08 Release type: Production Firmware version: 5.40.9.9 File name: P5534-E_5_40_9_9.bin Preceding release: 5.40.9.8 -------------------------------------------------------------------------------- UPGRADE INSTRUCTIONS ==================== The firmware can be upgraded using Axis Camera Management, HTTP or FTP. Please follow the instructions from the user's manual, the web page at http://www.axis.com/techsup/cam_servers/how_to_upgrade.htm or the file named howtoupgrade.txt. Corrections in 5.40.9.9 since 5.40.9.8 ====================================== 5.40.9.9:C01 Date format now correctly displayed in ACM. 5.40.9.9:C02 Corrected handling of #D text overlay, it is no longer needed to specify the camera source. 5.40.9.9:C03 Event configs now visible in server report. 5.40.9.9:C04 Fixed security vulnerability CVE-2016-5195. 5.40.9.9:C05 Fixed RTSP server stability issue. 5.40.9.9:C06 Fixed an issue when streaming over always-multicast. 5.40.9.9:C07 PTZ presetposall returns correct preset name. 5.40.9.9:C08 Fixed critical vulnerability ACV-116267. Known Bugs/Limitations ====================== 5.40.9.9:L01 Limiting the bandwidth to lower than 100kbit/s may lead to losing contact with the camera 5.40.9.9:L02 An uploaded bitmap overlay is made partially transparent unconditionally (black color). 5.40.9.9:L03 Maximum brightness will not result in a white image. 5.40.9.9:L04 No more than 4 privacy masks can be placed so close together that they are in the same view at any given time. 5.40.9.9:L05 Stream profile names are limited to alphanumerical characters. 5.40.9.9:L06 If RTSP authentication is switched off, streaming H.264 with QuickTime and other Apple compatible clients will not work as they require authentication of the RTSP, but do not allow HTTP authentication. 5.40.9.9:L07 Using ONVIF, the camera declares that is supports the Normalized Digital Zoom spaces but the camera does not and should not support those spaces. 5.40.9.9:L08 The ONVIF command 'gotoHomePosition' will go to the home position at a very slow speed, it will not use the default speed. 5.40.9.9:L09 If PTZ limits are changed, the camera must be restarted for the changes to be applied to the ONVIF API. 5.40.9.9:L10 If a Go to Preset movement includes an AutoFlip, the image will freeze during the whole movement. When the movement is done, the stream will start again. Movement will also be done at full speed, regardless of the current speed configuration. 5.40.9.9:L11 Automatic IR Cut Filter will not work if Auto Iris is off. 5.40.9.9:L12 When the automatic IR cut filter enables/disables the IR cut filter, it may trigger motion detection. 5.40.9.9:L13 Removing a Guard Tour while another Guard Tour is running will stop and restart the ongoing Guard Tour. 5.40.9.9:L14 Pan/tilt coordinate directions presented in the text overlay (#x #y) will not be rotated along with the image when rotation is 180. 5.40.9.9:L15 The image is always showed with zero rotation at the OSDI Zone Setup. 5.40.9.9:L16 Recording streams to SD Card with a total bit rate above 12Mbit/sec may cause missing frames/sequences. 5.40.9.9:L17 If a customer is trying to upload a very large file instead of a valid language file, a "404 page cannot be displayed" page is shown. 5.40.9.9:L18 Date modifiers "%m-%d-%Y" are not formatted correctly when used with folder name, SMTP subject and message. 5.40.9.9:L19 Zoom response is very slow when using the mouse scroll wheel in AMC. 5.40.9.9:L20 Pan/tilt/zoom control does not work using Java Applet if the Control Queue is enabled. 5.40.9.9:L21 Live view may display screen tearing (horizontal cut-lines) most prominent when panning the camera. 5.40.9.9:L22 Firefox can sometimes show white image flicker at the bottom of the video stream. This occurs on Windows XP and Windows Vista with Firefox versions 3.6.3-3.6.6 (possibly on later versions as well). 5.40.9.9:L23 Color parameter has no effect when pulling RTSP stream with color=0. 5.40.9.9:L24 Frame Size Control does not affect size of the snapshot taken with the upper right control that can be added to the Live View. 5.40.9.9:L25 It is recommended to unmount the SD Card before ejecting it. 5.40.9.9:L26 Recordings made with firmware earlier than 5.20 will not be readable on the SD Card from the 5.40 firmware. Backup important recordings and reformat the SD Card after the firmware upgrade. 5.40.9.9:L27 Check and repair is only available if the file system is ext4. 5.40.9.9:L28 When using action rule resulting in short recordings, it is recommended to extend post-event time. Application Developer Information ================================= The AXIS VAPIX Application Programming Interface version 3 is supported by the AXIS P5534-E. For more information, please refer to the AXIS VAPIX HTTP API specification version 3, part of the AXIS VAPIX API, available at www.axis.com. Supported AXIS VAPIX API Image Resolutions for AXIS P5534-E Resolution Exceptions ========== ========== 1280x720 800x450 480x270 320x180 1024x768 1) 1024x576 1) 800x600 1) 768x576 1) 720x576 1) 704x576 1) 704x480 1) 704x288 1) 704x240 1) 640x480 1) 640x360 1) 480x360 1) 384x288 1) 352x288 1) 352x240 1) 320x240 1) 240x180 1) 192x144 1) 176x144 1) 176x120 1) 160x120 1) 160x90 1) 1) Not visible in web user interface 90/270 degrees rotation is not supported.