FIRMWARE RELEASE NOTE ======================== Products affected: V5938 Release date: 2021-06-04 Release type: Production Firmware version: 10.6.0 Preceding release: 10.5.2 -------------------------------------------------------------------------------- Upgrade recommendations ======================== When updating the device, it is recommended to do an intermediate upgrade using an available AXIS OS LTS-release on the way to the desired AXIS OS version. For example, if the device currently is running AXIS OS 7.40 and you want to upgrade to the latest AXIS OS Active Track (Example: 10.1, October 2020) then you should do the upgrade in these steps: 7.40 => 8.40 LTS => 9.80 LTS => 10.1. More detailed recommendations can be found in the AXIS OS portal at https://www.axis.com/support/firmware. Upgrade the firmware according to the instructions given in howtoupgrade.txt, which is included in the firmware folder or according to instructions at https://www.axis.com/support/firmware. NOTE ======================== For latest information about Axis Cybersecurity, see: https://www.axis.com/support/product-security New features in 10.6.0 ================================================================================ 10.6.0:F1 MQTT subscription support added. With this support, it will be possible to use incoming MQTT messages as action triggers in the rule engine. 10.6.0:F2 Removed support for stream specific legacy overlays. The URL options for legacy image and legacy text overlay will not be supported any more. 10.6.0:F3 Added the possibility to show Day night Information switch in overlay text by using #dn. This will show both the current value and the threshold value for the day/night change. 10.6.0:F4 Added option to select which overlay should be used in a stream profile. 10.6.0:F5 Added "Audio clip playing" as a new condition in event system. 10.6.0:F6 HTTPS Ciphers are checked and unsupported ciphers removed on standard firmware upgrade 10.6.0:F7 Added a parameter to disable Apache & OpenSSL version in HTTP(S) responses in Plain Config -> System. 10.6.0:F8 Upgraded OpenSSL to 1.1.1k to increase overall minimum cyber security level. 10.6.0:F9 Updated Video Motion Detection to version 4.5.0. 10.6.0:F10 Support of stream specific legacy overlay is removed on Artpec platform. With this change, the URL option for both legacy image and text overlay will not be supported any more on Artpec platform. Features in 10.5.2 ================================================================================ 10.5.0:F1 RTSP and HTTP stream URL:s now allow for filtering overlays based on overlay type. This is done by setting 'overlays=' in the URL (only one value). 10.5.0:F2 Added support for Day-night shift in On Screen Control 10.5.0:F3 Updated pjsip to version 2.10 to increase overall cyber security. 10.5.0:F4 OpenSSL upgraded to 1.1.1j to fix CVE-2021-23841 and CVE-2021-23840. Corrections in 10.6.0 ================================================================================ 10.6.0:C1 Improved Motion Detection to handle scenes with extreme lighting changes , improving general behavior for applications that make use of this engine and data. 10.6.0:C2 Corrected an issue that made ceiling mounted cameras go to the wrong position when using absolute movements via VISCA commands. 10.6.0:C3 Corrected an issue that did not account for MTU packet fragmentation for IEEE 802.1x authentication. Previously the Axis device was not able to authenticate properly against an 802.1x network when the MTU was configured to 1410 or lower. 10.6.0:C4 Corrected an issue that on some occasions could prevent export of a part of a recording. 10.6.0:C5 Corrected an issue that in combination with some VMSes and low resolution could cause brief disconnections in the video stream. Corrections in 10.5.2 ================================================================================ 10.5.2:C1 Corrected an issue that on some occasions prevented an upgrade to firmware version 10.5.0. 10.5.2:C2 Corrected an issue that could cause O3C-based connections with the device to be interrupted. 10.5.0:C1 Increased the number of allowed characters for event condition name to 512. 10.5.0:C2 Corrected an issue that prevented the use of some special characters in ONVIF passwords. 10.5.0:C3 Corrected an issue that prevented the Axis device to respond with HTTP 403 Forbidden when the source-ip address was blocked when using PreventDOSAttack in Plain Config -> System. Previously HTTP 401 Unauthorized was returned. Known Bugs/Limitations ================================================================================ Supported AXIS VAPIX API Image Resolutions for V5938 ================================================================================ Resolution Exceptions Capture mode ------------ ------------ -------------- 3840x2160 2) 1920x1080 2) 3) 4) 1280x720 2) 3) 4) 5) 800x450 2) 3) 4) 5) 480x270 2) 3) 4) 5) 320x180 2) 3) 4) 5) 1280x960 1) 2) 3) 4) 1024x768 1) 2) 3) 4) 5) 1024x576 1) 2) 3) 4) 5) 800x600 1) 2) 3) 4) 5) 768x576 1) 2) 3) 4) 5) 720x576 1) 2) 3) 4) 5) 704x576 1) 2) 3) 4) 5) 704x480 1) 2) 3) 4) 5) 704x288 1) 2) 3) 4) 5) 704x240 1) 2) 3) 4) 5) 640x480 1) 2) 3) 4) 5) 640x360 1) 2) 3) 4) 5) 480x360 1) 2) 3) 4) 5) 384x288 1) 2) 3) 4) 5) 352x288 1) 2) 3) 4) 5) 352x240 1) 2) 3) 4) 5) 320x240 1) 2) 3) 4) 5) 240x180 1) 2) 3) 4) 5) 192x144 1) 2) 3) 4) 5) 176x144 1) 2) 3) 4) 5) 176x120 1) 2) 3) 4) 5) 160x120 1) 2) 3) 4) 5) 160x90 1) 2) 3) 4) 5) analyze 1) 2) 3) 4) 5) 1) Not visible in web user interface 2) 4K @ 25/30 fps 3) 1080p @ 50/60 fps 4) 1080p @ 25/30 fps 5) 720p @ 50/60 fps