FIRMWARE RELEASE NOTE ====================== Products affected: Q7404 Release date: 2018-03-26 Release type: Production Firmware version: 5.51.5 File name: Q7404_5_51_5.bin Preceding release: 5.50.4.10 -------------------------------------------------------------------------------- Upgrade instructions ==================== The firmware can be upgraded using Axis Camera Management, HTTP or FTP. Please follow the instructions from the user's manual, the web page at http://www.axis.com/techsup/cam_servers/how_to_upgrade.htm or the file named howtoupgrade.txt. NOTE ==================== For latest information about Axis Cybersecurity, see https://www.axis.com/se/sv/support/product-security. Corrections in 5.51.5 since 5.50.4.10 ===================================== 5.51.5:C01 Updated R2 GlobalSign Root Certificate to version 20170717. 5.51.5:C02 Corrected an issue that let the camera become unresponsive in rare occasions when connected to an AVHS system. 5.51.5:C03 Corrected critical vulnerability ACV-128401. Known Bugs/Limitations ====================== 5.51.5:L1 90 and 270 rotation can cause a drop in frame rate. 5.51.5:L2 If the device has ongoing continuous recordings and the device is restarted using the restart option in web interface, the current part of recordings(block) can not be accessed or downloaded through the web interface. 5.51.5:L3 AXIS Media Control client may stop displaying the H.264 video stream after the PC has been locked. 5.51.5:L4 Live view does not work with QuickTime player using default settings. Workaround: Disable Direct3D acceleration in Quicktime. 5.51.5:L5 To avoid corrupt recordings, it is recommended to unmount the SD Card before ejecting it. 5.51.5:L6 For actions based on PTZ events, it is not possible to use the #P (PTZ preset name) and #p (PTZ preset number) modifiers in the file names for network share uploads. 5.51.5:L7 Video overlay text size is a global setting and can not be set for each stream profile. 5.51.5:L8 Private keys need to be in a PKCS#1 format in order to function when installing Certificates. 5.51.5:L9 If downgrading to previous firmware version, a factory default is recommended after performing the downgrade. 5.51.5:L10 Using control queue with Java Applet may result in wrong queue positions if switching between admin and viewer users. 5.51.5:L11 On Windows shares, upload paths for events needs to be created on the share before use. 5.51.5:L12 AMC with IE10 does not work when using IPv6. 5.51.5:L13 Reboot is necessary after enabling SOCKS. 5.51.5:L14 When changing active https-certificate, the device needs to be restarted before it becomes active. 5.51.5:L15 Time modifiers used in the field "Create folder" is only used upon activation of the rule, hence no new folders are created with the current time during an active rule. To have new folders created with time modifiers you should add them in the "Base filename". 5.51.5:L16 Unclear error message when uploading audio clip with already existing name. Supported AXIS VAPIX API Image Resolutions for AXIS Q7404 ========================================================= Resolution Exceptions ========== ========== D1 720x576 2) 720x480 3) 4CIF 704x576 2) 704x480 3) 2CIF 704x288 2) 704x240 3) CIF 352x288 2) 352x240 3) QCIF 176x144 2) 176x120 3) VGA 640x480 1) analyze 1) 1) Not visible in web user interface 2) PAL mode resolution 3) NTSC mode resolution