FIRMWARE RELEASE NOTE ====================== Products affected: AXIS M5055 Release date: 2018-05-31 Release type: Production Firmware version: 6.53.2.1 Preceding release: 6.53.1.1 -------------------------------------------------------------------------------- Upgrade instructions ==================== Upgrade the firmware according to the instructions given at https://www.axis.com/ca/en/support/tecnical-notes/how-to-upgrade or howtoupgrade.txt, which is included in the firmware folder. NOTE ==================== For latest information about Axis Cybersecurity, see https://www.axis.com/se/sv/support/product-security. Corrections in 6.53.2.1 since 6.53.1.1 ======================================= 6.53.2.1:C01 General minor improvements to the platform. 6.53.2.1:C02 Corrected critical vulnerability ACV-128401. 6.53.2.1:C03 Corrected an issue were the event name in ACS was not shown correctly. 6.53.2.1:C04 Added support for 32kHZ audio sample rate. 6.53.2.1:C05 Added new resolution sets. 6.53.2.1:C06 The Apache webserver has been updated to version 2.4.29 to increase overall minimum cybersecurity standards. 6.53.2.1:C07 Updated the Portable UPnP SDK to 1.6.22 to increase the overall cyber security level. 6.53.2.1:C08 Corrected security vulnerability CVE-2016-2147. 6.53.2.1:C09 Corrected security vulnerability CVE-2016-2148. 6.53.2.1:C10 OpenSSL has been updated to version 1.0.2k to increase overall minimum cyber security level. 6.53.2.1:C11 The triple DES cipher is not selected as DEFAULT in the HTTPS settings to increase overall cyber security level. 6.53.2.1:C12 SSH has been updated to 7.5 to increase overall cybersecurity standards. 6.53.2.1:C13 Support for HTTP keep-alive connections via ONVIF. lowers the risk for security focused network infrastructure or unstable networks to block or drop PTZ control commands. Known Bugs/Limitations ====================== 6.53.2.1:L1 It is recommended to factory default the unit before making a downgrade if needed. 6.53.2.1:L2 Recording streams to SD card with a total bit rate above 12Mbit/sec may cause missing frames/sequences. 6.53.2.1:L3 When changing an active https-certificate, the product needs to be restarted for the new certificate to be applied. 6.53.2.1:L4 Video stream data will stop being sent when performing a PTZ test although the network session will remain. Some clients may disconnect if they do not detect video data. Normal operation will resume after the test is completed. 6.53.2.1:L5 The warning message "Wrong stream id, do not create image2d plugin for stream id -1" is stored in the server report on bootup. Supported AXIS VAPIX API Image Resolutions for AXIS M5055 ========================================================= Resolution Exceptions ========== ========== 1920x1080 1280x960 1280x720 800x600 800x450 640x480 640x360 480x360 480x270 320x240 320x180 1400x1050 1) 1440x900 1) 1024x768 1) 1024x640 1) 800x500 1) 768x576 1) 720x576 1) 704x576 1) 704x480 1) 704x288 1) 704x240 1) 640x400 1) 480x300 1) 384x288 1) 352x288 1) 352x240 1) 320x200 1) 240x180 1) 240x135 1) 192x144 1) 176x144 1) 176x120 1) 160x120 1) 160x100 1) 160x90 1) 80x50 1) 1) Not visible in web user interface