NOTE: On most Laser printers you have a top and bottom
margin of one line each, which means that you canprint 2 lines less than mentioned above. Note that the size of the margin may vary from printer to printer.
Incorrect line lengths or words wrapping:
- Check that the correct line length is set.
- Consult the users manual for IBM RPQ:s. There might be different RPQ settings that have to be made.
Nationality specific characters are not printed correctly:
- Set the printer connected to the same ASCII language as the
interface or set both the printer and the interface to your
national ASCII language.
- Characters like ÄÅÖäåö are printed as AAOaao. Make sure that you use the same ASCII Nationality as set
in the printer.
- Characters like ÄÅÖäåö are printed as []\{}|. Make sure that you have chosen the same SCS Nationality
as the system.
- Sometimes International #500 is used instead of your country's code page.
CECP Characters are not printed in LU-3 mode:
- Use the IBM 4224 printer emulation. CECP characters can only be printed in LU-1 if any other emulation is selected.
Underline and Bold problems:
- Underline and bold are printed as: Underline____ and BOLD textBOLD text
Check that the printer has CR support turned ON. Also check
that the parameter for MPP (Maximum print position) is not set to 0. If it is, the Interface will not send any CR:s to the printer.
Back
Other Problems
Problems when using the Cobra or Cobra+ interfaces without a power supply:
- The Cobra and Cobra+ are designed to work with a printer that
can supply 5v on pin 18 on the parallel connector. When entering the terminal set-up and executing a test function that
makes the printer print, the printer uses more power. In some there is not enough power to let the printer print and supply the Cobra at the same time. This can make the Cobra reset itself, and can be seen as if the terminal set-up is 'hanging'.
- To get around this problem, just connect a power supply to the
Cobra interface.
This problem can mainly be seen with the new Cobra+ interface, since it uses more power than the Cobra. Printers that are
affected by this problem are: OKI 320, 321, 390, 391, 393 and Facit P6060. Probably there are some more models.
Back
Connecting a PC to the PC-Host port
Problem Symptoms:
- Printer is not responding when printing from the PC
- Printer is printing Garbage
Solution:
- Check the parameter "PC-Host Timeout"in the interface, it
should be greater than 0, a value of 10 is recommended.
- If you use a program package like Windows, please make sure
that the settings inside the program are correct. Windows
overrides the settings made in the AUTOEXEC.BAT file in your PC.
Incorrect characters are printed when printing from the PC:
- Use the PC-Host and the Host-PC strings to switch between the different character sets used. Program the Host-PC string so that it sets the printer to PC Set 850 or PC Set II (code page 437) and the PC-Host string so that the original character set is used.
Back
Twinax
Hardware
Problems when installing the interface
Problem Symptoms:
- Interface is not communicating with the system.
- Interface is loosing contact with the system.
- Other equipment is thrown off the system.
Solution:
- Check the cabling after defective cables.
- Check that the last unit in the line has a terminator mounted or that the terminating switch is in position 1 or
that a self-terminating T-cable is mounted.
- Make sure that IBM approved cables or cabling system and
patch boxes have been used. Patch boxes like the TI-EX may
distort the signal so much, that no equipment can get
connection with the system.
- Make sure that you have set the correct device address.
Back
Problems during operation
Problem Symptoms:
- Interface is loosing contact with the system randomly.
- Other equipment is loosing contact with the system. Solution:
- See chapter "Problems when installing the Interface"
Back
Problems when upgrading from S/3x to AS/400
Some old products were designed and built before the AS/400 came. Therefore the AS/400 is not supported in old software
releases. Please check that you have the latest firmware for your interface.
Back
Problems with Terminal Setup
The Terminal Set-up is not coming up on the Screen:
- Check that the Cables are OK and correctly connected.
- The cables should be terminated in both ends. The Cobra and
AFP interfaces are provided with self-terminating T-Bar connectors.
- Make sure that the screen is set to a valid device address.
Back
Software
Problems when installing the interface
When you install a 3812/5219 emulating interface like the AX-3 Cobra 5219 you should always do the configuration on the
system as if you had an IBM 3812 printer.
The Interface is loosing contact with the Host:
- Some IBM terminals, like the 3477, have two or more device
addresses used for the terminal itself and the rest for printer ports on the
terminal.
- Make sure that the interface does not have the same device
address as any of these addresses or as any other device on
the same loop.
- Make sure that the configuration of the interface match with
the configuration in the system; i.e. if the interface is set for 4214 the system configuration should also say 4214.
Back
Problems during operation
Paper Positioning problems:
- Check that the page length in the printed document corresponds to the page length selected in the system and to
the page length set in the interface. If you have problems
getting the correct page length, make an EBCDIC Hex dump of a
document that covers the whole page and count the linefeeds
that are sent from the system. This will give you the correct page length setting.
Here are some usual Page lengths:
| Name |
Length in inches |
Length in lines at 6 Lpi |
|
8" |
48 |
| B5 |
10 1/8" |
60 |
| Executive |
10 1/2" |
63 |
| US Letter |
11" |
66 |
| A4 |
11 2/3" |
70 |
| 12" |
72 |
| US Legal |
14" |
84 |
NOTE: On most Laser printers you have a top and bottom margin of one line each, which means that you can
print 2 lines less than mentioned above. Note that the size of the margin may vary from printer
to printer.
Incorrect line lengths or words wrapping:
- Check that the correct line length is set.
- Consult the users manual for IBM RPQ:s. There might be different RPQ settings that have to be made.
Nationality specific characters are not printed correctly:
- Set the printer connected to the same ASCII language as the
interface, or set both the printer and the interface to your
national ASCII language.
- Characters like ÄÅÖäåö are printed as AAOaao. Make sure that
you use the same ASCII Nationality as set in the printer.
- Characters like ÄÅÖäåö are printed as [ ]\{}|. Make sure that
you have chosen the same SCS Nationality as the system.
- Sometimes International #5 is used instead of your country's code page.
Underline and Bold problems:
- Underline and bold are printed as: Underline_________ and
BOLD textBOLD text Check that the printer has CR support turned ON.
Back
Problems when upgrading from S/3x to AS/400
Some old products were designed and built before the AS/400 came. Therefore the AS/400 is not supported in old software
releases. Please check that you have the latest firmware for
your interface.
Back
4214 Specific problems
See Paper Positioning Problems. These kind of problems are typical for 4214 installations.
Back
5219 Specific problems
The font selected is not printed:
- Make sure that the FGID you selected is correctly defined in
the parameter list.
- Not all fonts mentioned in the manual can be reached without
reprogramming the parameter list. You may have to install a
font cartridge and reprogram the parameter list to get the
desired fonts. Check the users manual for a description of
how to program your own font definitions.
Back
Other Problems
Problems when using the Cobra or Cobra+ interfaces without a power supply:
- The Cobra and Cobra+ are designed to work with a printer that
can supply 5v on pin 18 on the parallel connector. When entering the terminal set-up and executing a test function that
makes the printer print, the printer uses more power. In some
there is not enough power to let the printer print and supply
the Cobra at the same time. This can make the Cobra reset itself, and can be seen as if the terminal set-up is 'hanging'.
- This problem can also be reproduced by setting the Cobra to a
new device address. Then the Cobra will reset itself each time
the warning message is printed.
- To get around this problem, just connect a power supply to the
Cobra interface.
This problem can mainly be seen with the new Cobra+ interface, since this uses more power than the Cobra. Printers that are
affected by this problem are: OKI 320, 321, 390, 391, 393 and Facit P6060. Probably there are some more models.
Back
Connecting a PC to the PC-Host port
Problem Symptoms:
- Printer is not responding when printing from the PC
- Printer is printing Garbage
Solution:
Check the parameter "PC-Host Timeout"in the interface, it should be greater than 0. A value of 10 is recommended.
- If you use a program package like Windows, please make sure
that the settings made in the program are correct. Windows
for example, overrides the settings made in the AUTOEXEC.BAT
file on your PC.
Incorrect characters are printed when printing from the PC:
- Use the PC-Host and the Host-PC strings to switch between the
different character sets used. Program the Host-PC string so
that it sets the printer to PC Set 850 or PC Set II and the
PC-Host string so that the original character set is used.
Back
Appendix A - Logon Mode Entry Examples
This Appendix describes the usual logon mode tables for Axis
standard Coax and Twinax products.
LU1 SCS entry for AX-7 products (non IPDS):
TITLE 'ISTTABLE.SCS'
******************************************************
*
* PRINTER WITH SNA CHARACTERSET
*
******************************************************
SCS MODEENT LOGMODE=SCS,
FMPROF=X'03'
TSPROF=X'03'
PRIPROT=X'B1',
SECPROT=X'90',
COMPROT=X'3080',
RUSIZES=X'87C6',
PSERVIC=X'01000000E100000000000000',
PSNDPAC=X'01',
SRCVPAC=X'01'
LU3 DSC entry for AX-7 products (non SCS):
TITLE 'ISTTABLE.DSC4K'
*****************************************************
*
* PRINTER WITH 4K BUFFER
*
*****************************************************
DSC4K MODEENT LOGMODE=DSC4K,
FMPROF=X'03'
TSPROF=X'03'
PRIPROT=X'B1',
SECPROT=X'90',
COMPROT=X'3080',
RUSIZES=X'8787',
PSERVIC=X'03000000000018502B507F00'
Local-Attached Entries for AX-3 3812/5219 emulating products:
IBM3812C MODEENT LOGMODE=IBM3812C,
FMPROF=X'03',
TSPROF=X'03',
PRIPROT=X'B1',
SECPROT=X'B0',
COMPROT=X'7080',
RUSIZES=X'85C7',
PSERVIC=X'014000010000000001000000',
PSNDPAC=X'02',
SRCVPAC=X'02',
SSNDPAC=X'00'
Communication-Attached Entries for AX-3 3812/5219 emulating products:
IBM3812 MODEENT LOGMODE=IBM3812,
FMPROF=X'03',
TSPROF=X'03',
PRIPROT=X'B1',
SECPROT=X'B0',
COMPROT=X'7080',
RUSIZES=X'8585',
PSERVIC=X'014000010000000001000000',
PSNDPAC=X'03',
SRCVPAC=X'03',
SSNDPAC=X'00'
Back
|