LED's

Search

LED's in the CD server, Axis StorPoint CD

Power LED is controlled by hardware always lit when power is connected.

Software controlled LED's:

Event Status LED CD LED Network LED
Power up sequence ON ON ON
  FLASH OFF OFF
  OFF ON( if CD inserted) FLASH
First disc inserted   ON  
Last disc removed   OFF  
Drive/disk error*   Flash (0,3 sec ON, 0,3 sec OFF)  
Packet arrived     ON (50 ms)
Error in EEPROM,
setting defaults
Flash (0,3 sec ON, 0,3 sec OFF) OFF OFF
Error in FLASH PROM, Flash (0,3 sec ON, 0,3 sec OFF) OFF Flash (0,3 sec ON, 0,3 sec OFF)
Error in SRAM, Flash (0,3 sec ON, 0,3 sec OFF) Flash (0,3 sec ON, 0,3 sec OFF) OFF
Error in DRAM/DIMM, In software r<3.07: Flash (0,3 sec ON, 0,3 sec OFF)
In software r>=3.07: Flash (0,45 sec ON, 0,15 sec OFF)
OFF OFF
DRAM/DIMM configuration error In software r<3.07: Flash (0,3 sec ON, 0,3 sec OFF)
In software r>=3.07: Flash (0,45 sec ON, 0,15 sec OFF)
In software r<3.07: Flash (0,3 sec ON, 0,3 sec OFF)
In software r>=3.07: Flash (0,45 sec ON, 0,15 sec OFF)
OFF
SW-HW combination errorr Flash (0,3 sec ON, 0,3 sec OFF) Flash (counter phase to network LED) Flash (counter phase to CD LED)
Illegal serial no. Flash (0,3 sec ON, 0,3 sec OFF) Flash (0,3 sec ON, 0,3 sec OFF) Flash (0,3 sec ON, 0,3 sec OFF)
Flash load failed Flash (0,3 sec ON, 0,3 sec OFF) OFF OFF
Flash loading Flash (0,5 sec ON, 0,5 sec OFF) Flash (0,5 sec ON, 0,5 sec OFF) Flash (0,5 sec ON, 0,5 sec OFF)
CD server is set to default Flash (0,3 sec ON, 0,3 sec OFF) OFF ON
Token-Ring loopback failure Flash (0,3 sec ON, 0,3 sec OFF) Flash (0,15 sec ON, 0,15 sec OFF) OFF
Token Ring speed error ON OFF Flash (0,3 sec ON, 0,3 sec OFF)

Axis specializes in professional network video and printing solutions